Nortec Staveley 2000A Metal Electric Flaw Detector
BASIC PERFORMANCE Frequency Range: 50 Hz - 12 MHz
Gain: 0 - 90 dB in 0.1 dB steps. The horizontal and vertical gains may be adjusted separately or together.
Rotation: Variable 0º - 359º
Sweep: Variable from 0.005 - 4 seconds per division
LowPassFilter: 10 - 500 Hz and wide band
HighPassFilter: Off, 2 to 500 Hz. 2 pole response
Probe Drive: 2, 6, 12 volts
Variable Persistence: Screen persistence can be varied from 0.1 - 5 seconds.
Probe Types: Absolute and differential in either bridge or reflection configuration. The instrument is fully compatible with NORTEC PowerLink™ probes.
Alarms: Can be set to trigger on positive or negative
Alarm Modes: 1-3 box gates, polar, sweep, conductivity, and coating thickness
Trace Storage: 20 traces can be stored for recall. The traces can be static or frozen. They can contain up to 60 seconds of movement. The traces are stored with the date and time of capture.
Program Storage: 120 instrument set-ups may be stored and recalled. The date and time of storage is recorded with each set-up.
Print Out: Provides a custom configurable report header containing the display screen data and probe parameters including serial number (PowerLink™ probes only)
Printers: Any serial printer
Inputs / Outputs Power: 7-pin connector to charge the internal battery and operate the instrument on AC power
RS-232: DB-9P connector, bi-directional serial data via RS-232
Probe Connector: 16-pin LEMO
Analog Outputs: Horizontal and Vertical outputs of both F1 and F2. +/- 5 volts, 1 volt per
Alarm Outputs: 9-pin analog and alarm output connector
VGA Output
General Dimensions: 9.5" L x 5.5" H x 3.6" D (215 mm x 165 mm x 92 mm)
Weight: 3.8 lbs. (1.7 Kg) with battery
Display: Customer-interchangeable QVGA displays (320 x 240 pixels): color or monochrome LCD, Hi-Brite electroluminescent
Operating Temperature: 14° F to 122° F (-10° C to 50° C), depending on configuration
Storage Temperature: -60° F to 160° F (-51° C to 71° C), depending on configuration
Humidity: 5 to 95%
Classification: Based on Class 2 specifications from the MIL-PRF-28800F handbook
Altitude: Maximum operating and non-operating altitude - 15,000 ft. (4600 m)
Hazardous Area Operation: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Association Code (NFPA 70), Section 500, and tested using MIL-STD-810F, Method 511.4, Procedure 1
Power Power Requirements: 85 to 240 volts, 50-60 Hz. External holder charges batteries outside the instrument. Charging time is typically 4 hours.
Low Battery Protection: Display bar graph "gas gauge" indicates approximate operating time.
Battery Operating Time: 8 hours (nominal depending on configuration)
Conductivity Frequency: 60 kHz or 480 kHz
Probe Type: NORTEC Conductivity Probe
Digital Conductivity Specification: Digital conductivity display from 0.9% to 110% IACS or 0.5 to 64 MS/m. Accuracy within +/- 0.5% IACS from 0.9% to 65% IACS and within +/- 1.0% of values over 62%. Meets or exceeds BAC 5651 specifications.
Non-Conductive Coating Thickness: Can measure non-conductive coating thickness from 0" to 0.015" (0 to 0.38 mm). Accuracy of +/- 0.001" (0.025 mm) over 0.00 to 0.015" (0 to 0.38 mm) range
Scanners Scanner Compatibility: Will operate all Olympus Nortec and other commercially available scanners
Waterfall Display: Stores up to 60 sweeps per hole and includes an on screen readout of the distance to the defect from the start of the scan (PS-5 only)
Dual frequency Frequency Extension: 50 Hz to 12 MHz
Second Frequency: 50 Hz to 3 MHz, 2nd frequency is an exac
Nortec Staveley 2000A Metal Electric Flaw Detector
- Brand: Metal-Detector
- Product Code: Nortec Staveley 2000A Metal Electric Flaw Detector
- Availability: In Stock
-
$1,921.74
- Ex Tax: $1,921.74